Temporary Chiller Hire Why use Watkins Chiller Hire?

Watkins Chiller Hire recognises companies and their clients, like people, are unique. We use our skills to solve your specific property / process temperature control and climate control problems and deliver temporary chillers, emergency cooling and temporary air conditioning hire solutions that truly meets your needs.

We have the a nationwide team of industry experts and 148 years of experience to manage the temporary space cooling systems, temporary process cooling at your working facilities. Watkins Hire will provide your businesses and your clients and energy efficient and cost effective temperature and climate control for spaces large and small with our range of temporary Chillers for Hire from 30kW to multi megawatt chiller rental units.

For a temporary chiller hire site survey, quotation or just fast friendly expert Facilities management support for chiller rental advice please call us now on one of the regional numbers below

Temporary chiller being delivered to a hospital
  • South East 0208 667 0088 / 07879 600992 - Email Andy Ellis
  • South West 01594 840025 / 07827 445512 - Email Jason Campbell
  • East & West Midlands 01922 634797 / 07825 123823 - Email Chris Easterlow
  • Northern East 01695 724888 / 07825 212914 - Email Jim Craig
  • South Wales 02920 277000 / 07827 445512 - Email Jason Campbell
  • North West 01695 724888 / 07500 962220 - Email Alan Ferguson
  • Scotland 01324 664222 / 07717 501118 - Email Rob Kemp
  • Northern Ireland 02890 950077 / 07795 241911 - Email Mark Walton
  • Ireland 00353 12480092 / 0044 7795 241911 - Email Mark Walton

Does your company operate from Multiple Office locations and do you want a single point of contact for your entire specialist HVAC hire requirements? Our dedicated National Accounts team can help.

Where & Why are Temporary Rental Chillers and Heat pump Chillers used?

  • Facilities managers (support to their client base)
  • Refrigeration companies (support to their client base)
  • M&E companies (support to their client base)
  • HVAC contractors (support to their client base)
  • Dairy (cooling Milk)
  • Plastics & Rubber (cooling injection moulding and extrusion machinery)
  • Carpets (cooling the rollers)
  • Abattoirs (cooling blood)
  • Chemicals (keeping the product cool and pressures down)
  • Poultry & Meat processing (cooling and adding weight to product with chilled water)
  • Bakery (cooling water to add to product)
  • Breweries & Beverages (cooling product for adding CO2 and maintaining temperature)
  • Hospitals MRI (cooling machine)
  • Packaging (cooling machinery)
  • Lasers (cooling machine)
  • Printers (keeping rollers cool)
  • Office blocks & Hotels (air conditioning with Water, DX chillers or Rooftops)
  • Pharmaceutical (cooling products through heat exchangers)
  • Oil Refinery (cooling products through heat exchangers)
  • Leisure Centres (Air Conditioning / De-humidifying)
  • Under floor heating (heat pumps)
  • Events (cooling and heating temporary structures and marquees)
  • ICE rinks (permanent and temporary)
  • Data centres and server rooms (IT equipment cooling)
  • Warehouse / Storage (product temperature / humidity control)
  • Factory (Machinery and operative cooling)
  • Nuclear Power Stations (machinery cooling)
  • Supermarket (cooling food storage area / Cooling the store)
  • Retail (shop floor cooling)
  • Defence (IT cooling/ comfort cooling)

Chiller Hire Model Summary - Click on model number for more information

    KwikCHILL 30 KwikCHILL 50 KwikCHILL 80 KwikCHILL 170 KwikCHILL 250 KwikCHILL 370 KwikCHILL 500
Cooling capacity @ 30°C Ambient air temperature
7°C flow / 12°C return ΔT 5°C
kW 33.6 52.6 82.3 170.1 257.1 371.8 491.4
ESEER at Eurovent conditions   2.90 3.44 3.61 3.88 3.88 3.56 3.76
Min. leaving water temperature °C -4 -12 -12 -12 -12 -12 -12
Max. leaving water temperature °C +12 +15 +15 +15 +15 +15 +15
Sound pressure level(10m) dB (A) 51 52 54 57 63 65 66
Typical Water Flow Rate L/s 1.64 2.51 3.93 8.13 12.29 17.77 23.49
Water Connections in 1" Camlock 2" Bauer 2" Bauer 3" Bauer 3" Bauer 4" Bauer 4" Bauer
Available Head Pressure kPa 70.6 191.6 162.1 162.1 127.5 153.4 120.2
Water Buffer Tank Volume L 100 370 410 570 570 600 600
Expansion Tank Volume L 35 25 25 35 35 50 50
Electrical Data v/ph/Hz 400/3/50 415/3/50 415/3/50 415/3/50 415/3/50 400/3/50 400/3/50
Generator Size Recommended kVA 45-kVA 75-kVA 100-kVA 200-kVA 300-kVA 450-kVA 550
Length (X) mm 1300 3560 3965 4155 4155 6090 6090
Width (Y) mm 1580 1230 1230 2440 2480 2530 2530
Height (Z) mm 2111 2600 2600 2600 2840 2590 2590

Call Us Free For All Your Temperature Control Hire Needs

Call us for free

Call 0500 526 696 and you will be in touch with an industrial steam boiler rental, heating boiler hire, chiller hire, portable air conditioner hire, evaporative cooling, portable heater, space heating or space cooling specialist who will discuss and understand your requirements for temporary cooling and heating or drying application, arrange site visits where necessary and provide you with a competitive quotation for our hire products and services.

Understanding your rental needs and providing a competitive solution.

Same day service

For over 150 years WatkinsHIRE have understood that it takes more than innovative, high performance temperature control rental products and superior technical service to help our customers, end users & facility managers compete and win in today's global marketplace. It takes a total commitment to understanding your cooling, heating and drying needs and the ability to provide the right temperature control rental solutions every time.